Effect of static pressure on acoustic transmittance of Albunex(R) microbubble suspensions
Effect of static pressure on acoustic transmittance of Albunex(R) microbubble suspensions
复制标题
DOI:
10.1121/1.415428
复制
发表时间:
1996-04-01
影响因子:
2.4
通讯作者:
Meltzer, RS
中科院分区:
文献类型:
--
作者:
Brayman, AA;Azadniv, M;Meltzer, RS
Albunex(R) (ALX), an albumin-stabilized microbubble echo contrast agent, is sensitive to pressures similar to those produced by the heart. The tested hypothesis was that the acoustic transmittance of ALX suspensions will increase with increasing hydrostatic pressure (P-s). The test involved an acoustic setup analogous;to a spectrophotometer. The acoustic transmittance of microbubble suspensions was strongly P-s dependent. Transmittance at 1 MHz was essentially zero at ambient pressure, increasing to similar to 50%, similar to 63%, and nearly 100% at P-s of 80, 120, and 400 mm Hg, respectively. The ultrasound pulses used to interrogate samples were without measurable effect on the acoustic transmittance of suspensions maintained at ambient pressure during experimental measurements. The data indicate that many of the microbubbles are destroyed at P-s comparable to those produced by the heart. (C) 1996 Acoustical Society of America.