LEUKOKINETIC STUDIES. X. BLOOD GRANULOCYTE KINETICS IN CHRONIC MYELOCYTIC LEUKEMIA.
LEUKOKINETIC STUDIES. X. BLOOD GRANULOCYTE KINETICS IN CHRONIC MYELOCYTIC LEUKEMIA.
复制标题
白细胞动力学研究。
DOI:
--
复制
发表时间:
1965
影响因子:
15.9
通讯作者:
M. Wintrobe
中科院分区:
文献类型:
--
作者:
J. Athens;S. Raab;O. Haab;D. Boggs;H. Ashenbrucker;G. Cartwright;M. Wintrobe
By the transfusion of granulocytes labeled in vitro with diisopropyl fluorophosphate (DFP32), it is possible to measure the size of the total blood granulocyte pool (TBGP), the distribution of granulocytes in the two subcompartments thereof, the blood granulocyte half disappearance time (tj), and the blood granulocyte turnover rate (GTR) (1-3). In preliminary reports from this laboratory (4-6) and in reports from other laboratories (7, 8) an increase in TBGP size, prolongation of blood granulocyte ti, and an increase in GTR have been described in a few patients with chronic myelocytic leukemia. In the present report 43 studies carried out on 29 patients with chronic myelocytic leukemia (CML) in various stages of their disease have been analyzed in an attempt to gain an understanding of these deviations from normal granulocyte kinetics. In addition, several studies designed to evaluate the cause of the long t4 values in patients with CML are presented. Similar studies of granulocyte kinetics in patients with polycythemia vera, subacute or chronic infections, myelofibrosis, or diseases of other kinds are presented in a companion paper.