Measurement of absorbed dose distributions in a plastic phantom irradiated by 40- and 65-MeV quasi-monoenergetic neutrons
Measurement of absorbed dose distributions in a plastic phantom irradiated by 40- and 65-MeV quasi-monoenergetic neutrons
复制标题
测量 40 MeV 和 65 MeV 准单能中子辐照的塑料体模中吸收剂量分布
DOI:
10.1016/s0168-9002(00)01022-6
复制
发表时间:
2001
影响因子:
1.4
通讯作者:
Y. Sakamoto
中科院分区:
文献类型:
--
作者:
Y. Nakane;Y. Sakamoto
In order to validate dose evaluation methods for radiation shielding design of accelerator facilities, absorbed dose distributions in a plastic phantom of 30×30×30cm3slab were measured for 40- and 65-MeV quasi-monoenergetic neutrons with a tissue-equivalent proportional counter and a tissue-equivalent ionization chamber. The measured distributions were compared with the calculated ones from the energy deposition of charged particles and neutron energy spectra by using the Monte Carlo codes, HETC-3STEP and MORSE-CG/KFA, respectively. As a result, it was revealed that the calculation method used in the present work was applicable to absorbed dose evaluation for intermediate energy neutrons with high accuracy.