Thermal cycling and ageing of a glass-ceramic sealant for planar SOFCs
Thermal cycling and ageing of a glass-ceramic sealant for planar SOFCs
复制标题
DOI:
10.1016/j.ijhydene.2011.04.083
复制
发表时间:
2011-09
影响因子:
7.2
通讯作者:
F. Smeacetto;A. Chrysanthou;M. Salvo;T. Moskalewicz;F. D. Bytner;L. C. Ajitdoss;M. Ferraris
中科院分区:
文献类型:
--
作者:
F. Smeacetto;A. Chrysanthou;M. Salvo;T. Moskalewicz;F. D. Bytner;L. C. Ajitdoss;M. Ferraris
Thermal cycling and thermal ageing tests were performed on Crofer22APU/glass-ceramic/Anode-Supported-Electrolyte (ASE) joined samples in air at the SOFC operating temperature of 800 °C. The Crofer22APU had been polished and preoxidised at 900 °C for 2 h. The diffusion behaviour at the two interfaces was examined and revealed slight diffusion of chromium and manganese from Crofer22APU into the glass-ceramic. No interactions, failure or crack formation were observed at the Crofer22APU/glass-ceramic interface and between the glass-ceramic and YSZ.