Measurements on Concorde of the Cosmic Radiation Field at Aviation Altitudes

Measurements on Concorde of the Cosmic Radiation Field at Aviation Altitudes
复制标题

协和式飞机在航空高度的宇宙辐射场测量

DOI:
10.1093/oxfordjournals.rpd.a033246
复制
发表时间:
2000
期刊:
影响因子:
--
通讯作者:
M. Bagshaw
M. Bagshaw
中科院分区:
--
文献类型:
--
作者:
D. Bartlett;L. Hager;D. Irvine;M. Bagshaw

文献摘要

被引文献

相似文献

报告了协和式飞机上平均航线剂量五年测量计划的前三年的结果。复杂的宇宙辐射场的测量是由一个被动测量仪,包括热释光探测器和蚀刻轨道探测器。总剂量当量的15%测定水平为100 μSv。有证据表明,被动测量仪提供了可靠的路径剂量测定。在1997年1月至1999年10月期间测量的从伦敦至纽约的协和式飞机回程航班的平均航线有效剂量为74 μSv。
The results are reported of the first three years of a five year measurement programme of average route doses on board Concorde. Measurements of the complex cosmic radiation field are made with a passive survey meter comprising thermoluminescent detectors and etched track detectors. The 15% determination level for total dose equivalent is 100 μSv. The evidence is that the passive survey meter provides a reliable determination of route dose. The average route effective dose for a return flight by Concorde between London and New York measured during the period January 1997 to October 1999, was 74 μSv.