Reduced quality of clot formation with gelatin-based plasma substitutes
Reduced quality of clot formation with gelatin-based plasma substitutes
复制标题
DOI:
10.1093/bja/80.2.204
复制
发表时间:
1998-02-01
影响因子:
9.8
通讯作者:
Ibbotson, RM
中科院分区:
文献类型:
--
作者:
Mardel, SN;Saunders, FM;Ibbotson, RM
We have studied, over a wide range of dilutions using techniques of clot weight, thrombelastography and scanning electron microscopy, the physical properties of a blood clot formed in vitro when fresh blood was diluted with gelatin-based colloid solutions compared with crystalloid controls. The colloid solutions tested (3.5% polygeline (Haemaccel) and 4% succinylated gelatin (Gelofusine)) produced clots that had reduced median weight (P