Fukushima Daiichi Unit 4 Accident

Fukushima Daiichi Unit 4 Accident
复制标题

福岛第一核电站 4 号机组事故

DOI:
10.1007/978-4-431-55543-8_3
复制
发表时间:
2015
影响因子:
11.4
通讯作者:
M. Ishikawa
M. Ishikawa
中科院分区:
工程技术1区
文献类型:
--
作者:
M. Ishikawa

文献摘要

被引文献

相似文献

4号机组因防护罩更换工作而停止运行,但它在4号机组的反应堆建筑中发生了神秘的氢气爆炸。大约5个月后,东京电力公司的工作人员发现了这个谜团的明确证据。3号机组和4号机组共用一个排气管,排放到环境中。他们发现了从排气烟囱流向4号机组的反向氢气的痕迹。我搜索了氢气爆炸的点火源,推测是由于室温升高,空气管道膨胀产生的火花。
The Unit 4 was out of operation for shroud exchange work, but it made a mysterious hydrogen explosion in the Unit 4 reactor building. It was about 5 months later that the TEPCO staff found a clear evidence of this mystery. The Unit 3 and the Unit 4 plant shares an exhaust stack for release to the environment. They found a trace of reverse hydrogen gas flow from the exhaust stack to the Unit 4 building. I searched for ignition sources of the hydrogen explosion and presumed that it was a spark on impact of the air duct expansion due to room temperature increase.