Performance of the xTAG® Gastrointestinal Pathogen Panel, a Multiplex Molecular Assay for Simultaneous Detection of Bacterial, Viral, and Parasitic Causes of Infectious Gastroenteritis
Performance of the xTAG® Gastrointestinal Pathogen Panel, a Multiplex Molecular Assay for Simultaneous Detection of Bacterial, Viral, and Parasitic Causes of Infectious Gastroenteritis
复制标题
DOI:
10.4014/jmb.1212.12042
复制
发表时间:
2013-07-01
影响因子:
2.8
通讯作者:
Topin, Francois
中科院分区:
文献类型:
--
作者:
Claas, Eric C.;Burnham, Carey-Ann D.;Topin, Francois
The xTAG (R) Gastrointestinal Pathogen Panel (GPP) is a multiplexed molecular test for 15 gastrointestinal pathogens. The sensitivity and specificity of this test were assessed in 901 stool specimens collected from pediatric and adult patients at four clinical sites. A combination of conventional and molecular methods was used as comparator. Sensitivity could be determined for 12 of 15 pathogens and was 94.3% overall. The specificity across all 15 targets was 98.5%. Testing for the pathogen identified was not requested by the physician in 65% of specimens. The simultaneous detection of these 15 pathogens can provide physicians with a more comprehensive assessment of the etiology of diarrheal disease.