Machine Independence of Ultrasound-Based Quantification of Vitreous Echodensities.
Machine Independence of Ultrasound-Based Quantification of Vitreous Echodensities.
复制标题
DOI:
10.1167/tvst.12.9.21
复制
发表时间:
2023-09-01
影响因子:
3
通讯作者:
Ketterling, Jeffrey A.
中科院分区:
文献类型:
--
作者:
Hoerig, Cameron;Nguyen, Justin H.;Mamou, Jonathan;Venuat, Cedric;Sebag, J.;Ketterling, Jeffrey A.
Quantitative ultrasound (QUS) provides objective indices of Vision Degrading Myodesopsia (VDM) that correlate with contrast sensitivity (CS). To date, QUS methods were only tested on a single ultrasound machine. Here, we evaluate whether QUS measurements are machine independent. In this cross-sectional study, 47 eyes (24 subjects; age = 53.2 ± 14.4 years) were evaluated with Freiburg acuity contrast testing (%Weber), and ultrasonography using 2 machines: one with a 15-MHz single-element transducer and one with a 5-ring, 20-MHz annular-array. Images were acquired from each system in sequential scans. Artifact-free, log-compressed envelope data were processed to yield three parameters (mean amplitude, M; energy, E; and percentage filled by echodensities, P50) and a composite score (C). A B-mode normalization method was applied to the 20-MHz datasets to match QUS parameters at both frequencies. Statistical analyses were performed to evaluate correlations among CS, E, M, P50, and C for both machines. QUS parameters from each machine correlated with CS (R ≥ 0.57, P < 0.001) and there was correlation between machines (R ≥ 0.84, P < 0.001). Correlations between CS and QUS parameters were statistically similar for both machines (P ≥ 0.14) except when the 20-MHz data were normalized (P = 0.04). Reproducibility of QUS parameters computed from 20-MHz data were satisfactory (52.3%–96.3%) with intraclass correlation values exceeding 0.80 (P < 0.001). The high correlation between QUS parameters from both machines combined with a statistically similar correlation to CS suggests QUS is an effective, machine-independent, quantitative measure of vitreous echodensities. QUS may be applied across clinical ophthalmic ultrasound scanners and imaging frequencies to effectively evaluate VDM.
登录
查看更多内容
DOI:
10.1097/iae.0000000000003781
发表时间:
2023-07-01
影响因子:
3.3
作者:
Boneva, Stefaniya K.;Nguyen, Justin H.;Sebag, J.
通讯作者:
Sebag, J.
影响因子:
1.4
作者:
Dennis, RJ;Beer, JMA;Thompson, WT
通讯作者:
Thompson, WT
DOI:
10.1097/iae.0000000000000065
发表时间:
2014-06-01
影响因子:
3.3
作者:
Sebag, Jerry;Yee, Kenneth M. P.;Sadun, Alfredo A.
通讯作者:
Sadun, Alfredo A.
影响因子:
1.4
作者:
Buhren, Jens;Terzi, Evdoxia;Kohnen, Thomas
通讯作者:
Kohnen, Thomas
影响因子:
2.4
作者:
INSANA, MF;WAGNER, RF;HALL, TJ
通讯作者:
HALL, TJ