HEMODYNAMIC EFFECTS OF THE ANASTOMOSES IN THE MODIFIED BLALOCK-TAUSSIG SHUNT: A NUMERICAL STUDY USING A 0D/3D COUPLING METHOD
HEMODYNAMIC EFFECTS OF THE ANASTOMOSES IN THE MODIFIED BLALOCK-TAUSSIG SHUNT: A NUMERICAL STUDY USING A 0D/3D COUPLING METHOD
复制标题
改良 BLALOCK-TAUSSIG 分流术中吻合的血流动力学效应:使用 0D/3D 耦合方法的数值研究
DOI:
10.1142/s0219519415500177
复制
发表时间:
2015-02-01
影响因子:
0.8
通讯作者:
Qiao, Aike
中科院分区:
文献类型:
--
作者:
Zhao, Xi;Liu, Youjun;Qiao, Aike
The modified Blalock-Taussig (BT) shunt is a palliative surgery which can help the tetralogy of Fallot (TOF) patient increase the blood oxygen saturation by interposing a systemic-to-pulmonary artery shunt. Two typical anastomotic shapes are frequently used in clinical practice: the end-to-side (ETS) and the side-to-side (STS) anastomosis. This paper examines the hemodynamic influence of the anastomotic shape in the modified BT shunt. Three models with different anastomotic shapes were reconstructed. The ETS anastomoses were applied in the first model. For the innominate artery (IA) and the pulmonary artery (PA) in the second model, the ETS and the STS anastomosis were applied, respectively. Finally, the STS anastomoses were applied in the third model. The 0D/3D coupling method was used to perform a numerical simulation by coupling the three-dimensional (3D) artery model with a zero-dimensional (0D) lumped parameter model for the cardiovascular system. The simulation results showed that the perfusion into the left and right PA in Model 1 was unbalanced. Swirling flow appeared in the shunt in Model 3, but the shunt flow rate in Model 3 was lower. The ETS anastomosis at the PA may cause unbalanced blood perfusion into the left and right PA. Conversely, the STS anastomosis can make the blood perfusion more balanced. Otherwise,the STS anastomosis at the IA could generate a swirling flow in the shunt which may provide a better hemodynamic environment while decreasing the pulmonary perfusion.