Effects Of The CT Display Window On Detectability Of Large And Small Lesions
Effects Of The CT Display Window On Detectability Of Large And Small Lesions
复制标题
CT显示窗口对大、小病灶可检性的影响
DOI:
--
复制
发表时间:
1984
期刊:
影响因子:
--
通讯作者:
R. Swensson
中科院分区:
文献类型:
--
作者:
D. A. Twible;P. Judy;R. Swensson
The effects of CT display window width and lesion size on observer performance were studied by measurements of contrast-detail "thresholds" and lesion detectability (using ROC analysis). Both methods of measuring observers' perceptual performance showed that lesions became less visible as the width of the display window increased, and that the magnitude of this effect was greater for larger (lower contrast) lesions than for smaller ( higher contrast) lesions. Manipulations of the CT display window did not affect the information content of the physical image, as measured by actual calculations of signal-to-noise ratio for a "lesion-matched" filter. Therefore, the effects of display window on observer performance were attributed to psychophysical properties of the human visual system.