QUANTITATIVE ANALYSIS OF BIO-MEDICAL SAMPLES OF VERY SMALL QUANTITIES BY THE STANDARD-FREE METHOD

QUANTITATIVE ANALYSIS OF BIO-MEDICAL SAMPLES OF VERY SMALL QUANTITIES BY THE STANDARD-FREE METHOD
复制标题

采用无标样方法对极少量生物医学样品进行定量分析

DOI:
10.1142/s0129083597000205
复制
发表时间:
1997
期刊:
International Journal of PIXE
影响因子:
--
通讯作者:
K. Matsuda
K. Matsuda
中科院分区:
--
文献类型:
--
作者:
K. Sera;S. Futatsugawa;S. Hatakeyama;Y. Saitoh;K. Matsuda

文献摘要

被引文献

相似文献

将自行研制的无标样方法应用于L小于1 mg或小于1μ的生物医学样品中,常规内标法无法准确应用。结果表明,NIST-牛肝样品中钾浓度的正确值接近0.5 mg。并将该方法用于少量血清和全血样品的测定,结果令人满意。对于容易从背膜上剥离的样品,如血清和全血,也可以用带有粘合剂的碳带作为背膜,发现这种方法也适用。此外,对于使用特殊设计的X射线吸收体的情况,无标准方法被证实是有效的。
A standard-free method developed by ourselves has been applied to bio-medical samples of less than 1 mg or less than 1 μl, to which an ordinary internal standard method can not be accurately applied. As the result, correct values of potassium concentration in NIST-Bovine liver samples of nearly 0.5 mg were obtained. Furthermore, the standard-free method has been applied to small quantity of serum and whole-blood samples, and satisfactory results were obtained. For samples which easily peel off from a backing film, such as serum and whole blood, a carbon tape with an adhesive agent was also used as a backing film, and it is found that this method is also applicable. Moreover, the standard-free method was confirmed to be effective for a case where a specially designed x-ray absorber is used.