A method for determination of low carbon monoxide concentration in blood.
A method for determination of low carbon monoxide concentration in blood.
复制标题
一种测定血液中低一氧化碳浓度的方法。
DOI:
--
复制
发表时间:
1966
期刊:
影响因子:
--
通讯作者:
B. Söderström
中科院分区:
文献类型:
--
作者:
H. Linderholm;T. Sjöstrand;B. Söderström
A method is described for the measurement of the CO content of blood, particularly at low concentrations. The error of a single determination was 1–3 per cent of the total amount of CO (range 0.7–70 μl) present in the analyzed sample. At an ordinary CO content of about 0.1 ml CO/100 ml blood the error was about ± 0.002 ml CO/100 ml blood (S.D.). Different procedures for the release of CO from the blood were compared. With K3 Fe(CN)6 and H2SO4 equal and slightly smaller amounts of CO were obtained than with KH(JO3)2, if blood with a low CO content was analyzed. Evidently KH(JO3)2, although less than some other chemical agents (K2Cr2O7 and NaOH), causes extra CO formation from the blood. In spite of the error due to this extra CO formation there were advantages to use KH(JO3)2 for analysis in higher ranges of CO concentrations, when this small error became insignificant. If extraction of CO from the blood with reagents such as K3 Fe(CN)6, H2SO4 or KH(JO3)2 took place at a high O2 partial pressure slightly larger amounts of CO were obtained than with extraction in“vacuum” or in an atmosphere of N2. The results indicate that small amounts of CO may be formed during procedures used for the release of CO from blood, probably due to oxidative break down of hemoglobin.