Receptive syringe sharing and infection risk: to clean or not to clean.
Receptive syringe sharing and infection risk: to clean or not to clean.
复制标题
接受注射器共用和感染风险:清洁或不清洁。
DOI:
10.1086/653840
复制
发表时间:
2010
期刊:
影响因子:
--
通讯作者:
Gyarmathy,VAnna
中科院分区:
文献类型:
--
作者:
Gyarmathy,VAnna
To the Editor—It was with great interest that I read the recent article by Hagan et al [1], who assessed predictors of hepatitis C virus (HCV) seroconversion among a cohort of 483 injection drug users in 5 US cities. The authors performed a set of 8 multivariate analyses elaborating on the association of incident HCV infection with different combinations of injecting equipment sharing, and they found that the shared use of drug preparation equipment was significantly associated with HCV seroconversion, whereas receptive syringe sharing was not. In their discussion, the authors explain the lack of association of receptive syringe sharing with HCV seroconversion with the deliberate risk reduction strategy of participants to share syringes only with low-risk partners. In a cross-sectional study among injecting drug users in Hungary, we explored associations with prevalent HCV infections [2]. To examine the role played by syringe cleaning in prevalent HCV infection, we created 2 variables for receptive syringe sharing: receptive syringe sharing that always included cleaning before sharing, and receptive syringe sharing that did not always include cleaning before sharing. We found that, although receptive sharing of (1-piece) syringes when the syringes were always cleaned before sharing was not associated with prevalent HCV infection (multivariate adjusted odds ratio [AOR], 0.7 [95% confidence interval {CI}, 0.2–1.9]), receptive syringe sharing when the syringe was not always cleaned showed a strong association (multivariate AOR, 3.1 [95% CI, 1.1–8.9]). We concluded that, in our study population, thorough cleaning of used 1-piece syringes before receptive sharing diminished the risk of HCV infection to the level of using sterile syringes [2].After having read the article by Hagan et al [1], we performed a post hoc analysis of our data and combined the 2 receptive syringe sharing variables (sharing and always cleaning, and sharing but not always cleaning) into 1 variable (sharing, regardless of cleaning). In this post hoc multivariate analysis—containing the 1 sharing variable and all other variables from the original multivariate model—there was no association between receptive syringe sharing and HCV infection (multivariate AOR, 1.40 [95% CI, 0.66–2.97]; P p). Although a cross-sectional study is. 384 inferior to a prospective cohort study concerning study design, our post hoc findings suggest that the lack of association between receptive syringe sharing and HCV seroconversion reported by Hagan et al [1] may be the result of confounding by syringe cleaning. If their questionnaire also assessed syringe cleaning, it would be interesting to see if including into their multivariate models 2 variables (sharing and always cleaning, and sharing but not always cleaning) instead of 1 variable (sharing, regardless of cleaning) would change their results.