Temporal change of an extracted H− current by injecting pulse laser light into the extraction region of an H− ion source
Temporal change of an extracted H− current by injecting pulse laser light into the extraction region of an H− ion source
复制标题
通过将脉冲激光注入 H− 离子源的提取区域,提取的 H− 电流随时间变化
DOI:
10.1063/1.1427757
复制
发表时间:
2002
影响因子:
1.6
通讯作者:
M. Sasao
中科院分区:
文献类型:
--
作者:
Y. Matsumoto;M. Wada;T. Kasuya;M. Sasao
The temporal change of the H− beam current extracted from a volume-production-type negative ion source by injecting a Nd-YAG laser beam into the ion source plasma was measured. The measured change was about 0.3% of the dc H− beam current. The validity of the method was confirmed using Ar plasma which showed no photodetachment signal. The contribution of the local H− density upon the extracted beam was investigated by changing the distance between the center of the laser beam and the plasma grid. The result showed that the contribution took the maximum at about 8 mm distance from the laser beam center to the plasma grid surface.