New Structure of the Magnetic Fluid Linear Pump Gwan Soo Park and Sang Ho Park
New Structure of the Magnetic Fluid Linear Pump Gwan Soo Park and Sang Ho Park
复制标题
磁流体线性泵的新结构 Gwan Soo Park 和 Sang Ho Park
DOI:
--
复制
发表时间:
2000
期刊:
影响因子:
--
通讯作者:
S. H. Park
中科院分区:
文献类型:
--
作者:
G. Park;S. H. Park
In this paper, we developed a new structure of the magnetic fluid linear pump. The magnetic field could be focused effectively in the tube by using permalloy yoke. The magnetic re- luctance could be reduced remarkably so that we could reduce de- vice size up to 37.8% and increase pumping pressure up to 144.8%. The optimum width of the yoke was designed and compared with measurements.