[Evaluation of the level of residual monomer in acrylic denture base materials having different polymerization properties].
[Evaluation of the level of residual monomer in acrylic denture base materials having different polymerization properties].
复制标题
[不同聚合性能的丙烯酸树脂义齿基托材料中残留单体水平的评价]。
DOI:
--
复制
发表时间:
1988
期刊:
影响因子:
--
通讯作者:
O. Timlioğlu
中科院分区:
文献类型:
--
作者:
B. Kalipçilar;L. Karaagaclioglu;U. Hasanreisoğlu;O. Timlioğlu
Summary
The aim of this study was to evaluate the level of residual monomer in acrylic denture base materials having different polymerization properties. The investigation included a conventional-type acrylic cured under heat and pressure, as well as a pour-type resin polymerized by an injection-moulding technique at room temperature and under pressure. It was found that the residual monomer content ranged from 0·22–0·54% in pour-type resin, and from 0·23–0·52% in routinely used resins when the specimens were analysed by high performance liquid chromatography. These findings revealed that there were no significant differences between the two types of acrylic in terms of their residual monomer content.