Development of a new corona discharge based ion source for high resolution time-of-flight chemical ionization mass spectrometer to measure gaseous H2SO4 and aerosol sulfate

Development of a new corona discharge based ion source for high resolution time-of-flight chemical ionization mass spectrometer to measure gaseous H2SO4 and aerosol sulfate
复制标题

DOI:
10.1016/j.atmosenv.2015.08.028
复制
发表时间:
2015-10
影响因子:
5
通讯作者:
Jun Zheng;Dongsen Yang;Yan Ma;Mindong Chen;Jin Cheng;Shizheng Li;Ming Wang
Jun Zheng;Dongsen Yang;Yan Ma;Mindong Chen;Jin Cheng;Shizheng Li;Ming Wang
中科院分区:
环境科学与生态学2区
文献类型:
--
作者:
Jun Zheng;Dongsen Yang;Yan Ma;Mindong Chen;Jin Cheng;Shizheng Li;Ming Wang

文献摘要

被引文献

相似文献

A new corona discharge (CD) based ion source was developed for a commercial high-resolution time-of-flight chemical ionization mass spectrometer (HRToF-CIMS) (Aerodyne Research Inc.) to measure both gaseous sulfuric acid (H2SO4) and aerosol sulfate after thermal desorption. Nitrate core ions (NO3−) were used as reagent ions and were generated by a negative discharge in zero air followed by addition of excess nitrogen dioxide (NO2) to convert primary ions and hydroxyl radicals (OH) into NO3−ions and nitric acid (HNO3). The CD-HRToF-CIMS showed no detectable interference from hundreds parts per billion by volume (ppbv) of sulfur dioxide (SO2). Unlike the atmospheric pressure ionization (API) ToF-CIMS, the CD ion source was integrated onto the ion–molecule reaction (IMR) chamber and which made it possible to measure aerosol sulfate by coupling to a filter inlet for gases and aerosols (FIGAERO). Moreover, compared with a quadrupole-based mass spectrometer, the desired HSO4−signal was detected by its exact mass ofm/z96.960, which was well resolved from the potential interferences of HCO3−⋅(H2O)2(m/z97.014) and O−⋅H2O⋅HNO3(m/z97.002). In this work, using laboratory-generated standards the CD-HRToF-CIMS was demonstrated to be able to detect as low as 3.1 × 105molecules cm−3gaseous H2SO4and 0.5 μg m−3ammonium sulfate based on 10-s integration time and two times of the baseline noise. The CD ion source had the advantages of low cost and a simple but robust structure. Since the system was non-radioactive and did not require corrosive HNO3gas, it can be readily field deployed. The CD-HRToF-CIMS can be a powerful tool for both field and laboratory studies of aerosol formation mechanism and the chemical processes that were critical to understand the evolution of aerosols in the atmosphere.