An investigation on the use of removal-diffusion theory for BNCT treatment planning: a method for determining proper removal-diffusion parameters.
An investigation on the use of removal-diffusion theory for BNCT treatment planning: a method for determining proper removal-diffusion parameters.
复制标题
使用去除扩散理论进行 BNCT 治疗计划的研究:确定适当去除扩散参数的方法。
DOI:
10.1118/1.1386424
复制
发表时间:
2001
期刊:
影响因子:
3.8
通讯作者:
J. Niemkiewicz
中科院分区:
文献类型:
--
作者:
B. J. Albertson;T. Blue;J. Niemkiewicz
This paper outlines a method for determining proper removal-diffusion parameters to be used in removal-diffusion theory calculations for the purpose of BNCT treatment planning. Additionally, this paper demonstrates that, given the proper choice of removal-diffusion parameters, removal-diffusion theory may provide an accurate calculation technique for determining absorbed dose distributions for the purpose of BNCT treatment planning. For a four-group, one-dimensional calculation in water, this method was used to determine values for the neutron scattering cross sections, neutron removal cross sections, neutron diffusion coefficients, and extrapolation distances. These values were then used in a one-dimensional DIF3D calculation. The results of the DIF3D calculation showed a maximum deviation of 2.5% from a MCNP calculation performed for the same geometry.