EVALUATION FOR RESIDUAL AXIAL FORCE OF CORRODED HIGH TENSILE BOLTS
EVALUATION FOR RESIDUAL AXIAL FORCE OF CORRODED HIGH TENSILE BOLTS
复制标题
腐蚀高强度螺栓残余轴向力的评估
DOI:
10.14455/isec.res.2014.8
复制
发表时间:
2014
期刊:
影响因子:
--
通讯作者:
Yumi Mori
中科院分区:
文献类型:
--
作者:
R. Satake;K. Fujii;Yumi Mori
This paper presents a method for evaluating the residual axial force of corroded high strength bolts in experiments, and analysis measuring the axial force of corroded high strength bolts. In order to reproduce the axial force reduction due to corrosion, the test specimens were made by cutting the bolt head widthwise or the height-wise with an initial axial force. The curve of axial force lowering is prepared with a reduced thickness in height and width of bolts as a parameter. Therefore, the residual axial force can be estimated by the thickness reduction of bolt. Moreover, we measured the residual axle force of real corroded high strength bolts, taken from a bridge removed from service for a long time, and inspected an axis drop curve. In order to classify corrosion shapes, we measured the three-dimensional surface shape of corroded high strength bolts without contact, and considered the relationship between the surface shape of corroded high strength bolts and the axial force reduction.