Performance of the ASTRO-E hard X-ray detector
Performance of the ASTRO-E hard X-ray detector
复制标题
ASTRO-E 硬 X 射线探测器的性能
DOI:
10.1109/tns.2002.801491
复制
发表时间:
2002
影响因子:
1.8
通讯作者:
D. Yonetoku
中科院分区:
文献类型:
--
作者:
M. Tashiro;T. Kamae;K. Makishima;Tadayuki Takahashi;T. Murakami;Y. Fukazawa;M. Kokubun;K. Nakazawa;A. Nomachi;A. Yoshida;Y. Ezoe;N. Isobe;N. Iyomoto;J. Kataoka;J. Kotoku;M. Kouda;S. Kubo;A. Kubota;Y. Matsumoto;T. Mizuno;G. Madejski;Y. Okada;N. Ota;H. Ozawa;G. Sato;M. Sugiho;M. Sugizaki;I. Takahashi;H. Takahashi;T. Tamura;C. Tanihata;Y. Terada;Y. Uchiyama;S. Watanabe;K. Yamaoka;D. Yonetoku
This paper summarizes the design and performance of the hard X-ray detector constructed for the ASTRO-E satellite. The detector utilizes the GSO/BGO well-type phoswich counters in a compound-eye configuration to achieve an extremely low background level of a few /spl times/ 10/sup -5/ counts s/sup -1/ cm/sup -2/ keV/sup -1/. The GSO scintillators installed in the BGO active shield wells are sensitive to 30-600 keV photons, while the 2-mm-thick silicon PIN diodes, placed in front of each GSO crystal, cover the 10-60 keV energy band with a spectral resolution of /spl sim/3.5-keV full-width at half-maximum. The design goals, of both low background and high energy resolution, in the hard X-ray bands were verified through the preflight calibration experiments.