Quantification of manganese in human hand bones: a feasibility study
Quantification of manganese in human hand bones: a feasibility study
复制标题
DOI:
10.1088/0031-9155/53/15/005
复制
发表时间:
2008-08-07
影响因子:
3.5
通讯作者:
McNeill, F. E.
中科院分区:
文献类型:
--
作者:
Aslam;Pejovic-Milic, A.;McNeill, F. E.
Manganese (Mn) is a nutrient essential for regulating neurological and skeletal functions in the human body, but it is also toxic when humans are excessively exposed to Mn. Blood (or serum/plasma) and other body fluids reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive measurement of Mn stored in bone, using in vivo neutron activation analysis. Following feasibility studies, a first pilot study, using neutron activation analysis to measure Mn in the bones of the hand of ten healthy male human subjects, was conducted with the approval of the concerned research ethics boards. The participants of this study had no known history of exposure to Mn. Two volunteers were excluded from this study due to technical problems with their measurements. The inverse variance weighted mean value of Mn/Ca for the participants of this study is 0.12 +/- 0.68 mu g Mn/g Ca which is comparable within uncertainties with the estimated range of 0.16-0.78 mu g Mn/g Ca and mean value of 0.63 +/- 0.30 mu g Mn/g Ca derived from cadaver data. It is recommended to investigate the use of the diagnostic technique for in vivo measurements of workers exposed occupationally to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. The technique needs further development to improve the precision of in vivo measurements in the non-exposed population.Manganese is both an essential element to human health and also toxic when humans are exposed to excessive levels, particularly by means of inhalation. Biological monitoring of manganese exposure is problematic. It is subject to homeostasis; levels in blood (or serum/plasma) reflect only the most recent exposure and rapidly return to within normal ranges, even when there has been a temporary excursion in response to exposure. In this context, we have been developing a non-invasive technique for measurement of manganese stored in bone, using in vivo neutron activation analysis. Following preliminary feasibility studies, the technique has been enhanced by two significant infrastructure advances. A specially designed irradiation facility serves to maximize the activation of manganese with respect to the dose of ionizing radiation. Secondly, an array of eight NaI(Tl) crystals provides a detection system with very close to 4 pi geometry. This feasibility study, using neutron activation analysis to measure manganese in the bones of the hand, takes two features into account. Firstly, there is considerable magnesium present in the bone and this produces a spectral interference with the manganese. The Mg-26(n, gamma)Mg-27 reaction produces gamma-rays of 0.843 MeV from the decay of Mg-27, which interfere with the 0.847 MeV gamma-rays from the decay of Mn-56, produced by the Mn-55(n, gamma)Mn-56 reaction. Secondly, this work provides estimates of the levels of manganese to be expected in referent subjects. A revised estimate has been made from the most recent literature to explore the potential of the technique as a suitable means of screening patients and people exposed to excessive amounts of Mn who could develop many-fold increased levels of Mn in bones as demonstrated through various animal studies. This report presents the enhancements to the neutron activation system, by which manganese can be measured, which resulted in a detection limit in the hand of human subjects of 1.6 mu g/g Ca. It also provides a revised estimate of expected referent levels of manganese in bone, now estimated to be 0.63 mu g/g Ca and highlights the extent to which technical improvements will be required to further extend the application of the technique for in vivo measurements in non-exposed human subjects.