Measurement of the Impurity Diffusivity of Cu in Fe by Laser Induced Breakdown Spectrometry
Measurement of the Impurity Diffusivity of Cu in Fe by Laser Induced Breakdown Spectrometry
复制标题
激光诱导击穿光谱法测量 Fe 中 Cu 的杂质扩散率
DOI:
10.4028/www.scientific.net/ddf.237-240.266
复制
发表时间:
2005
影响因子:
--
通讯作者:
T. Okino
中科院分区:
文献类型:
--
作者:
C. Lee;Jung Han Lee;B. Lee;Yong I. Lee;T. Shimozaki;T. Okino
The impurity diffusion coefficients of Cu in Fe have been determined in the temperature range of 1073 - 1163 K by means of Laser Induced Breakdown Spectrometry (LIBS). The volume diffusion coefficients for Cu impurity diffusion in a-iron found in this work are in good agreement with the previously published result. The grain boundary diffusion coefficient gb D s d was also calculated using the volume diffusivity and processing the tails of the measured profiles. The values of the activation energy for volume and grain boundary diffusion were approximately 280 and 161 kJmol-1, respectively. This indicates the possibility of a monovacancy diffusion mechanism in case of volume diffusion. The results for the diffusion coefficients are Dv= 2.2 ×10-2exp(-280 kJmol-1/RT) m2s-1 and gb D s d = 2.6 ×10-11exp(-161 kJmol-1/RT) m3s-1.