Measurement of internal charge distribution of electric double layer capacitor by PEA method
Measurement of internal charge distribution of electric double layer capacitor by PEA method
复制标题
PEA法测量双电层电容器内部电荷分布
DOI:
10.1109/ceidp.2004.1364196
复制
发表时间:
2004
期刊:
影响因子:
--
通讯作者:
Toshio Bouno
中科院分区:
文献类型:
--
作者:
D. Tashima;Y. Hirata;M. Otsubo;C. Honda;Toshio Bouno
In this study, electrolyte was injected into an electric double layer capacitor (EDLC) after degas treatment in vacuum and directly in air, respectively, and the internal charge distribution in the EDLC was examined by the pulsed electro acoustic (PEA) method. It was found that volume charge density in the case of injection of electrolyte after degas treatment in vacuum is about seven times compared with that injected directly in air. It was thought that sufficient electrolyte can be injected into the polarized microporous electrode by degas in vacuum and more electric charge can be saved. Moreover, the sound velocity in the material is examined. It has been understood that electrostatic capacity gradually increases with the rise of applied voltage. The electrostatic capacity was estimated by the PEA method and the energy conversion method, respectively. The results from two methods are in good agreement.