In Situ Cross-Calibration of In-Fiber Bragg Grating and Electrical Resistance Strain Gauges for Structural Monitoring Using an Extensometer
In Situ Cross-Calibration of In-Fiber Bragg Grating and Electrical Resistance Strain Gauges for Structural Monitoring Using an Extensometer
复制标题
DOI:
10.1109/jsen.2009.2026990
复制
发表时间:
2009-11-01
影响因子:
4.3
通讯作者:
Grattan, Kenneth T. V.
中科院分区:
文献类型:
--
作者:
Grattan, Simon K. T.;Taylor, Su E.;Grattan, Kenneth T. V.
This study addresses the direct calibration of optical fiber strain sensors used for structural monitoring and is carried out in situ. The behavior of fiber-Bragg-grating-based sensor systems when attached to metal bars, in a manner representative of their use as reinforcement bars in structures, was examined and their response calibrated. To ensure the validity of the measurements, this was done using an extensometer with a further calibration against the response of electrical resistance strain gauges, often conventionally used, for comparison. The results show a repeatable calibration generating a suitable geometric factor of extension to strain for these sensors, to enable accurate strain data to be obtained when the fiber-optic sensor system is in use in structural monitoring applications.