Measurement of Radiated Power Loss on EAST
Measurement of Radiated Power Loss on EAST
复制标题
DOI:
10.1088/1009-0630/13/5/07
复制
发表时间:
2011-10
影响因子:
1.7
通讯作者:
Y. Duan;Liqun Hu;S. Mao;P. Xu;Kaiyun Chen;Shiyao Lin;G. Zhong;J. Zhang;Ling Zhang;
中科院分区:
文献类型:
--
作者:
Y. Duan;Liqun Hu;S. Mao;P. Xu;Kaiyun Chen;Shiyao Lin;G. Zhong;J. Zhang;Ling Zhang;
A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal response (<0.5 s) and flat spectral sensitivity in the range from ultra-violet to X-ray. Two 16-channel AXUV arrays are installed in EAST to view the whole poloidal cross-section of plasma. Based on the diagnostic system, typical radiation distributions for both limiter and divertor plasma are obtained and compared. As divertor detachment occurs, the radiation distribution in X-point region is observed to vary distinctly. The total radiation power losses in discharges with different plasma parameters are briefly analyzed.