Development and definition of a simplified scanning procedure and scoring method for Haemophilia Early Arthropathy Detection with Ultrasound (HEAD-US)
Development and definition of a simplified scanning procedure and scoring method for Haemophilia Early Arthropathy Detection with Ultrasound (HEAD-US)
复制标题
DOI:
10.1160/th12-11-0874
复制
发表时间:
2013-06-01
影响因子:
6.7
通讯作者:
Morfini, Massimo
中科院分区:
文献类型:
--
作者:
Martinoli, Carlo;Alberighi, Ornella Della Casa;Morfini, Massimo
The aim of this study was to develop a simplified ultrasound scanning procedure and scoring method, named Haemophilia Early Arthropathy Detection with UltraSound [HEAD-US], to evaluate joints of patients, with haemophilic arthropathy. After an initial consensus-based pro, cess involving a multidisciplinary panel of experts, three comprehensive and evidence-based US scanning procedures to image the elbow, knee and ankle were established with the aim to increase sensitivity in detection of early signs of joint involvement while keeping the technique easy and quick to perform. Each procedure included systematic evaluation of synovial recesses and selection of a single osteochondral surface for damage analysis. Based on expert consensus, a simplified scoring system based on an additive scale was created to define the joint status and, in perspective, to offer a tool to evaluate disease progression and monitor the result of treatment in follow-up studies.