Characterization of scintillators for lost alpha diagnostics on burning plasma experiments
Characterization of scintillators for lost alpha diagnostics on burning plasma experiments
复制标题
DOI:
10.1063/1.2228743
复制
发表时间:
2006-10
影响因子:
1.6
通讯作者:
M. Nishiura;N. Kubo;T. Hirouchi;T. Ido;T. Nagasaka;T. Mutoh;S. Matsuyama;M. Isobe;A. Okamoto;K. Shinto;S. Kitajima;M. Sasao;M. Nakatsuka;K. Fujioka
中科院分区:
文献类型:
--
作者:
M. Nishiura;N. Kubo;T. Hirouchi;T. Ido;T. Nagasaka;T. Mutoh;S. Matsuyama;M. Isobe;A. Okamoto;K. Shinto;S. Kitajima;M. Sasao;M. Nakatsuka;K. Fujioka
The characteristics of light output by ion beam irradiations under high ion fluxes have been measured for three kinds of scintillators: ZnS:Ag deposited on the glass plate, Y3Al5O12:Ce powder stiffened with a binder, and Y3Al5O12:Ce ceramics sintered at high temperature. The ion beam flux in the range from 1012to1013ions∕(cm2s) is irradiated to simulate the burning plasma experiments. The decrease of light output has been observed by long time ion irradiation. The deterioration of ZnS:Ag deposited scintillator is most serious. The deterioration has been improved for the scintillators of Y3Al5O12:Ce with a binder and that sintered. Their applications to ITER lost alpha diagnostics are discussed.