Non-invasive diagnosis of early pulmonary disease in PECAM-deficient mice using infrared pulse oximetry

Non-invasive diagnosis of early pulmonary disease in PECAM-deficient mice using infrared pulse oximetry
复制标题

DOI:
10.1016/j.yexmp.2009.07.008
复制
发表时间:
2009-10-01
影响因子:
3.6
通讯作者:
Schenkel, Alan R.
Schenkel, Alan R.
中科院分区:
医学3区
文献类型:
--
作者:
Early, Merideth A.;Lishnevsky, Marta;Schenkel, Alan R.

文献摘要

被引文献

相似文献

Pulse oximetry is a common tool for detecting reduced pulmonary function in human interstitial lung diseases. It has not previously been used in a mouse model of interstitial lung disease. Further, platelet endothelial cell adhesion molecule deficient mice rarely show symptoms until disease is advanced.Using blood oxygen saturation, different stages of disease could be identified in a non-invasive manner. These stages could be correlated to pathology. Collagen deposition, using Picrosirius Red, did correlate with blood oxygen saturation. These studies are the first to show the use of an infrared pulse oximetry system to analyze the progression of a fibrotic interstitial lung disease in a mouse model of the human diseases. Further, these studies show that an early alveolar damage/enlargement event precedes the fibrosis in this mouse model, a stage that represents the best targets for disease analysis and prevention. This stage does not have extensive collagen deposition. Most importantly, targeting this earliest stage of disease for therapeutic intervention may lead to novel treatment for human disease. (C) 2009 Elsevier Inc. All rights reserved.