Near-infrared spectroscopy might be a useful tool for predicting the risk of vascular complications after pediatric liver transplants: Two case reports
Near-infrared spectroscopy might be a useful tool for predicting the risk of vascular complications after pediatric liver transplants: Two case reports
复制标题
DOI:
10.1111/petr.13089
复制
发表时间:
2018-02-01
影响因子:
1.3
通讯作者:
Takeuchi, Mamoru
中科院分区:
文献类型:
--
作者:
Shiba, Juntaro;Satoh, Masaaki;Takeuchi, Mamoru
In patients that have undergone liver transplants, a postoperative reduction in the blood flow of the liver graft represents a critical complication. We recently encountered an interesting phenomenon; that is, we found that the rSO(2) level of the liver graft, as measured by NIRS, drops in patients that subsequently require an emergency liver biopsy. An 8-month-old female and an 8-month-old male underwent living donor liver transplants for biliary atresia. In both cases, a reduction in rSO(2) was detected before an emergency liver biopsy was required. As a result of biopsy examinations, both patients were diagnosed with acute graft rejection. NIRS might be useful for graft management during the postoperative period in pediatric patients that undergo liver transplantation. After a liver transplant, a reduction in the rSO(2) of the graft might be indicative of the onset of vascular complications.