Position sensitivity of the TIGRESS 32-fold segmented HPGe clover detector
Position sensitivity of the TIGRESS 32-fold segmented HPGe clover detector
复制标题
TIGRESS 32 倍分段 HPGe 三叶草探测器的位置灵敏度
DOI:
10.1016/j.nima.2004.11.031
复制
发表时间:
2005
影响因子:
1.4
通讯作者:
L. M. Watters
中科院分区:
文献类型:
--
作者:
C. Svensson;G. Hackman;C. Pearson;M. Schumaker;H. C. Scraggs;M. Smith;C. Andreoiu;A. Andreyev;R. Austin;G. Ball;A. Boston;R. Chakrawarthy;R. Churchman;N. Cowan;T. Drake;P. Finlay;P. Garrett;G. Grinyer;B. Hyland;B. Jones;J. Martin;A. C. Morton;A. Phillips;R. Roy;F. Sarazin;N. Starinsky;J. Valiente;J. C. Waddington;L. M. Watters
Sensitivity to the locations of γ-ray interactions within a 32-fold segmented clover-type HPGe detector has been investigated through 90∘Compton scattering of 661.6keVγ-rays from a collimated Cs137 source. A mean position sensitivity of 0.44mm at an energy of 373keV is deduced by comparing the average pulse shapes for net charge collecting signals, as well as transient induced signals in neighbouring contacts, from 1007 pairs of three-dimensionally localized interaction points. The reconstruction of individual event locations based on a χ2comparison with the measured set of basis waveforms is presented.