Research to Practice: Assessment of Left Ventricular Global Longitudinal Strain for Surveillance of Cancer Chemotherapeutic-Related Cardiac Dysfunction.
Research to Practice: Assessment of Left Ventricular Global Longitudinal Strain for Surveillance of Cancer Chemotherapeutic-Related Cardiac Dysfunction.
复制标题
DOI:
10.1016/j.jcmg.2018.07.005
复制
发表时间:
2018-08
期刊:
影响因子:
--
通讯作者:
Marwick TH
中科院分区:
文献类型:
--
作者:
Yang H;Wright L;Negishi T;Negishi K;Liu J;Marwick TH
AFTER A DECADE OF SPECKLE STRAIN, THE TECHNIQUE SEEMS SET TO JOIN A GROUP OF TRANSFORMATIVE innovations that have changed how we use echocardiography. Global longitudinal strain (GLS) has now been recommended as a means of follow-up for patients at risk of cancer therapeutic–related cardiac dysfunction (1). However, although the use of GLS has spread, many clinicians are unfamiliar with the practical process of data acquisition and continue to rely on ejection fraction. The purpose of this iPIX is to facilitate the acquisition and measurement of GLS for following patients in unfamiliar hands by illustrating its application with the most commonly used equipment in the United States.Strain is analyzed by post-processing of apical views (Table 1). The derivation of GLS from speckle tracking is slightly different with the software of different manufacturers (Figures 1 to 4), but there are 5 unifying steps: 1) view selection; 2) definition of end systole; 3) tracing; 4) assessing tracking quality; and 5) integration. The analysis steps require minimal time and experience, but need to be followed—strain should not be used as a “black box.” GLS is a simple parameter that expresses longitudinal shortening as a percentage and is calculated from all modern strain software. There are a number of ways of displaying different aspects of strain, including waveforms (to illustrate contraction delay and temporal dispersion in multiple segments) and parametric displays (which illustrate spatial dispersion throughout the cardiac cycle). These displays are of value for the assessment of regional strain. They are also of use in the quality control of testing subclinical LV dysfunction—where both temporal and spatial dispersion of strain are somewhat unusual and their presence should provide an alert to the presence of possible artifact.
DOI:
10.1016/j.echo.2014.07.012
发表时间:
2014-09-01
影响因子:
6.5
作者:
Plana, Juan Carlos;Galderisi, Maurizio;Lancellotti, Patrizio
通讯作者:
Lancellotti, Patrizio
DOI:
10.1016/j.echo.2015.06.011
发表时间:
2015-10-01
影响因子:
6.5
作者:
Farsalinos, Konstantinos E.;Daraban, Ana M.;Voigt, Jens-Uwe
通讯作者:
Voigt, Jens-Uwe