Spiral CT of the larynx.
Spiral CT of the larynx.
复制标题
喉部螺旋CT。
DOI:
--
复制
发表时间:
1994
期刊:
影响因子:
--
通讯作者:
J. Suojanen
中科院分区:
文献类型:
--
作者:
J. Suojanen;S. Mukherji;F. J. Wippo;J. Suojanen
PURPOSE
To compare conventional and spiral CT studies of the larynx.
METHODS
Ten patients had both conventional and spiral CT studies of the neck using 5-mm section collimation and 5-mm increments. The spiral scans also were reconstructed at 2-mm increments. Five patients had two spiral CT larynx studies with 5-mm and 2-mm collimation. Two observers independently rated the visibility of laryngeal structures and absence of motion artifact in the studies and assigned values from 1 (poor) to 4 (excellent).
RESULTS
The spiral scan images showed less motion artifact (1.9 versus 3.6) and better anatomic detail (2.3 versus approximately 2.6). Thinner reconstruction intervals and sections gave better anatomic detail (2.3 versus approximately 3.3). Interobserver kappa was 0.65.
CONCLUSION
Spiral is better than conventional CT scanning when studying the larynx.