Using transformer parasitics for resonant converters - a review of the calculation of the stray capacitance of transformers
Using transformer parasitics for resonant converters - a review of the calculation of the stray capacitance of transformers
复制标题
DOI:
10.1109/ias.2005.1518701
复制
发表时间:
2005
期刊:
影响因子:
--
通讯作者:
J. Biela;Johann W. Kolar
中科院分区:
文献类型:
--
作者:
J. Biela;Johann W. Kolar
Parasitic capacitances of conventional transformers can be used as resonant elements in resonant DC-DC converters in order to reduce the overall system size. For predicting the values of the parasitic capacitors without building the transformer different approaches for calculating these capacitances are compared. A systematic summary of the known approaches is given and missing links between the different theories and missing equations are added. Furthermore, a new simple procedure for modelling parasitic capacitances which is based on the known approaches is proposed. The resulting equations are verified by measurements on four different high voltage transformers.