Measurements of the heat loss through an insulated roof
Measurements of the heat loss through an insulated roof
复制标题
通过隔热屋顶测量热损失
DOI:
--
复制
发表时间:
1981
期刊:
影响因子:
--
通讯作者:
T. Ward
中科院分区:
文献类型:
--
作者:
B. R. Anderson;T. Ward
In situ measurements have been made of the heat loss through a roof insulated at ceiling level with glass fibre quilt. The results compare favourably with predicted values obtained from standard U-value calculations. An investigation of the dependence of the thermal resistance of the insulation on the air speed at its exposed upper surface showed that the performance of the insulation was not affected by air speed within the range 0 to 0.1 m/s. The air speeds within the loft space were only weakly correlated with external wind speed, and were mostly within the range 0 to 0.1 m/s, for external wind speeds up to 10 m/s.