YOUNGS MODULUS OF TRABECULAR AND CORTICAL BONE MATERIAL - ULTRASONIC AND MICROTENSILE MEASUREMENTS
YOUNGS MODULUS OF TRABECULAR AND CORTICAL BONE MATERIAL - ULTRASONIC AND MICROTENSILE MEASUREMENTS
复制标题
DOI:
10.1016/0021-9290(93)90042-d
复制
发表时间:
1993-02-01
影响因子:
2.4
通讯作者:
TURNER, CH
中科院分区:
文献类型:
--
作者:
RHO, JY;ASHMAN, RB;TURNER, CH
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p