Demonstration of a high resolution x-ray detector for medical imaging
Demonstration of a high resolution x-ray detector for medical imaging
复制标题
用于医学成像的高分辨率 X 射线探测器演示
DOI:
10.1117/12.2320723
复制
发表时间:
2018
期刊:
影响因子:
--
通讯作者:
Stankus, Brian
中科院分区:
文献类型:
--
作者:
Kingon, Angus I.;Morse, Theodore F.;Weber, Peter M.;Akif, Adil;Gupta, Rajiv;Murphy, Timothy P.;Cherepy, Nerine J.;Adams, Bernhard W.;Bifano, Thomas G.;Stankus, Brian
In digital X-ray imaging, a crucial factor determining image resolution of all indirect detection systems is the spread of light in the X-ray scintillator. Currently deployed clinical x-ray detectors, with a resolution between 75 and 300 microns, are affected by such spread of light. This work demonstrates the significantly improved the resolution of an indirect X-ray scintillation detector using a new structuring approach The new structured scintillator consists of three main components: a high optical quality ‘channel plate’, a reflective material within the capillaries of the channel plate, and a polymer-based scintillating material that is incorporated in the capillaries. Channel plates, which are utilized for a variety of optical applications, are produced from bundles of hollow drawn borosilicate glass fibers, with repeated bundling and drawing reducing the diameter of the core and capillary pores down to values as low as 5 microns. These bundles are then cut to make high quality plates (‘channel plates’) with a thickness around 1 mm. Channel plates contain geometrically ordered capillary channels (about 5 million channels per square cm). The channel walls were coated with a 70 nm thick coating of Al2O3:W using atomic layer deposition (ALD) to optically confine the photoemission within the channel. The optical channel plates were infiltrated with a new bismuth-based scintillating polymer developed at Lawrence Livermore National Laboratory, with a photon yield of > 30,600 photons/keV for X-ray energies of 20-30 keV, a range of interest for mammography. The new scintillator plate was used to experimentally demonstrate an X-ray resolution of 10 microns (or 50 linepairs/ mm), an approximately 7 times improvement over existing scintillating detectors. A structured scintillator plate, coupled with a digital detection system may be used to improve the spatial resolution in applications such as mammography, radiography, and computed tomography.
登录
查看更多内容
影响因子:
35
作者:
Yakunin S;Sytnyk M;Kriegner D;Shrestha S;Richter M;Matt GJ;Azimi H;Brabec CJ;Stangl J;Kovalenko MV;Heiss W
通讯作者:
Heiss W
DOI:
--
发表时间:
2012
期刊:
Nuclear Science Symposium and Medical Imaging Conference
影响因子:
--
作者:
N. Cherepy;R. Sanner;T. Tillotson;S. Payne;P. Beck;S. Hunter;L. Ahle;P. Thelin
通讯作者:
P. Thelin
DOI:
--
发表时间:
2012
期刊:
影响因子:
--
作者:
B. L. Rupert;N. Cherepy;B. Sturm;R. Sanner;S. Payne
通讯作者:
S. Payne
DOI:
--
发表时间:
2003
期刊:
SPIE Medical Imaging
影响因子:
--
作者:
E. Buhr;S. Günther;U. Neitzel
通讯作者:
U. Neitzel