Simultaneous analysis of multiple urinary biomarkers for the evaluation of oxidative stress by automated online in-tube solid-phase microextraction coupled with negative/positive ion-switching mode liquid chromatography-tandem mass spectrometry.
Simultaneous analysis of multiple urinary biomarkers for the evaluation of oxidative stress by automated online in-tube solid-phase microextraction coupled with negative/positive ion-switching mode liquid chromatography-tandem mass spectrometry.
复制标题
通过自动在线管内固相微萃取结合负/正离子转换模式液相色谱-串联质谱法,同时分析多种尿液生物标志物,以评估氧化应激。
DOI:
10.1002/jssc.201800175
复制
发表时间:
2018
影响因子:
3.1
通讯作者:
Hiroyuki Kataoka
中科院分区:
文献类型:
--
作者:
Akihiro Saito;Mariko Hamano;Hiroyuki Kataoka
This study described an automated online method for the simultaneous determination of 8‐isoprostane, 8‐hydroxy‐2′‐deoxyguanosine, and 3‐nitro‐l‐tyrosine in human urine. The method involves in‐tube solid‐phase microextraction using a Carboxen 1006 PLOT capillary column as an extraction device, followed by liquid chromatography with tandem mass spectrometry using a CX column and detection in the negative/positive switching ion‐mode by multiple reaction monitoring. Using their stable isotope‐labeled internal standards, each of these oxidative stress biomarkers showed good linearity from 0.02 to 2.0 ng/mL. Their detection limits (S/N = 3) were 3.4–21.5 pg/mL, and their intra‐ and inter‐day precisions (relative standard deviations) were >3.9 and 6.5% (n= 5), respectively. This method was applied successfully to the analysis of urine samples, without any other pretreatment and interference peaks.