Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial
复制标题
DOI:
10.1001/jamanetworkopen.2018.5474
复制
发表时间:
2018-11-01
影响因子:
13.8
通讯作者:
Myers, Kyle J.
中科院分区:
文献类型:
--
作者:
Badano, Aldo;Graff, Christian G.;Myers, Kyle J.
Using a dataset of over 1.9 million messages posted on Twitter by about 25,000 ISIS sympathizers, we explore how ISIS makes use of social media to spread its propaganda and recruit militants from the Arab world and across the globe. By distinguishing between violence-driven, theological, and sectarian content, we trace the connection between online rhetoric and key events on the ground. To the best of our knowledge, ours is one of the first studies to focus on Arabic content, while most literature focuses on English content. Our findings yield new important insights about how social media is used by radical militant groups to target the Arab-speaking world, and reveal important patterns in their propaganda efforts.IMPORTANCE Expensive and lengthy clinical trials can delay regulatory evaluation of innovative technologies, affecting patient access to high-quality medical products. Simulation is increasingly being used in product development but rarely in regulatory applications.OBJECTIVES To conduct a computer-simulated imaging trial evaluating digital breast tomosynthesis (DBT) as a replacement for digital mammography (DM) and to compare the results with a comparative clinical trial.DESIGN, SETTING, AND PARTICIPANTS The simulated Virtual Imaging Clinical Trial for Regulatory Evaluation (VICTRE) trial was designed to replicate a clinical trial that used human patients and radiologists. Images obtained with in silico versions of DM and DBT systems via fast Monte Carlo x-ray transport were interpreted by a computational reader detecting the presence of lesions. A total of 2986 synthetic image-based virtual patients with breast sizes and radiographic densities representative of a screening population and compressed thicknesses from 3.5 to 6 cm were generated using an analytic approach in which anatomical structures are randomly created within a predefined breast volume and compressed in the craniocaudal orientation. A positive cohort contained a digitally inserted microcalcification cluster or spiculated mass.MAIN OUTCOMES AND MEASURES The trial end point was the difference in area under the receiver operating characteristic curve between modalities for lesion detection. The trial was sized for an SE of 0.01 in the change in area under the curve (AUC), half the uncertainty in the comparative clinical trial.RESULTS In this trial, computational readers analyzed 31 055 DM and 27 960 DBT cases from 2986 virtual patients with the following Breast Imaging Reporting and Data System densities: 286 (9.6%) extremely dense, 1200 (40.2%) heterogeneously dense, 1200 (40.2%) scattered fibroglandular densities, and 300 (10.0%) almost entirely fat. The mean (SE) change in AUC was 0.0587 (0.0062) (P < .001) in favor of DBT. The change in AUC was larger for masses (mean [SE], 0.0903 [0.0081) than for calcifications (mean [SE], 0.0268 [0.004]), which was consistent with the findings of the comparative trial (mean [SE]. 0.065 [0.017] for masses and -0.047 [0.032] for calcifications).CONCLUSIONS AND RELEVANCE The results of the simulated VICTRE trial are consistent with the performance seen in the comparative trial. While further research is needed to assess the generalizability of these findings, in silico imaging trials represent a viable source of regulatory evidence for imaging devices.