Determination of tannic acid after precipitation with bovine serum albumin by visible light scattering in a flow injection system
Determination of tannic acid after precipitation with bovine serum albumin by visible light scattering in a flow injection system
复制标题
DOI:
10.1007/s00604-010-0301-9
复制
发表时间:
2010-03
影响因子:
5.7
通讯作者:
T. Cheng;Hsien-Yi Hsiao;Chien-Yu Chung;Po-Chung Chen;Richie L. C. Chen
中科院分区:
文献类型:
--
作者:
T. Cheng;Hsien-Yi Hsiao;Chien-Yu Chung;Po-Chung Chen;Richie L. C. Chen
Tannic acid can form a precipitate with bovine serum albumin (BSA), and this was explored for its determination using a flow injection system along with detection via light scattering at 600 nm. The results on light scattering are confirmed using a particle sizing method. Scattering signals are negligible compared to the background generated by BSA in solutions with a pH of <4 or >8. Any precipitates on the wall of the flow cell pipeline were effectively removed by using a sodium dodecyl sulfate washing solution. The analytical range is from 70 to 250 µgmL-1of tannic acid. The results imply that increasing BSA concentrations will enhance sensitivity and analytical ranges. The system can be used in solutions of pH values between 5 and 7. The results correlated closely (r2> 0.97) with those obtained by the ferrous tartrate method when analyzing a single tannic acid and two tea tannins.