Boosting the Temperature Detection Accuracy of Luminescent Ratiometric Thermometry via a Multifunction Fit Strategy
Boosting the Temperature Detection Accuracy of Luminescent Ratiometric Thermometry via a Multifunction Fit Strategy
复制标题
通过多功能拟合策略提高发光比例测温法的温度检测精度
DOI:
10.1021/acs.jpcc.8b06778
复制
发表时间:
2018
影响因子:
3.7
通讯作者:
Zhang Zhiguo
中科院分区:
文献类型:
--
作者:
Li Leipeng;Qin Feng;Zhou Yuan;Zheng Yangdong;Zhao Hua;Zhang Zhiguo
The influence of fit strategy on the temperature detection accuracy of luminescence ratiometric thermometry is investigated here. In the range of 303–783 K, the typical2H11/2/4S3/2–4I15/2upconversion emission lines of Er3+embedded in calcium tungstate are investigated as a function of temperature. It is found that using the conventional one-function fit method over the whole temperature range leads to a mean error of 3.47 K. By contrast, the strategy, namely, dividing the whole board temperature range into several narrow ones and using several fit functions over separate temperature scopes, is proposed and studied. It is demonstrated that as the number of the divided temperature scopes is increased, the measured temperature readout gradually approaches to the true value of the temperature. When the number is set to be six, the temperature error sharply goes down to 0.41 K, suggesting that the newly proposed multi-function fit strategy is superior to the traditional one-function fit method, especially when a board temperature scope is involved. The reason responsible for this phenomenon is also discussed.