Ultrasound attenuation measurements using a reference phantom with sound speed mismatch.

Ultrasound attenuation measurements using a reference phantom with sound speed mismatch.
复制标题

DOI:
10.1177/016173461103300404
复制
发表时间:
2011-10
期刊:
影响因子:
2.3
通讯作者:
Hall TJ
Hall TJ
中科院分区:
工程技术4区
文献类型:
--
作者:
Nam K;Rosado-Mendez IM;Rubert NC;Madsen EL;Zagzebski JA;Hall TJ

文献摘要

参考文献

被引文献

相似文献

Ultrasonic attenuation may be measured accurately with clinical systems and array transducers by using reference phantom methods (RPM) to account for diffraction and other system dependencies on echo signals. Assumptions with the RPM are that the speeds of sound in the sample (csam) and in the reference medium (cref) are the same and that they match the speed assumed in the system beamformer (cbf). This work assesses the accuracy of attenuation measurements by the RPM when these assumptions are not met. Attenuation was measured for two homogeneous phantoms, one with a speed of sound of 1500m/s and the other with a sound speed of 1580m/s. Both have an attenuation coefficient approximately equal to that of the reference, in which the speed of sound is 1540m/s. Echo signals from the samples and the reference were acquired from a Siemens S2000 scanner with a 9L4 linear array transducer. Separate acquisitions were obtained with cbf at its default value of 1540m/s, and when it was set at values matching the speeds of sound of the phantoms. Simulations were also performed using conditions matching those of the experiment. RPM measured attenuation coefficients exhibited spatially-dependent biases when csam differed from cbf and cref. Mean errors of 19% were seen for simulated data, with the maximum errors in attenuation measurements occurring for regions of interest near the transmit focus. Biases were minimized (mean error with simulated data was 5.6%) using cbf that matched csam, and assuring that power spectra used for attenuation computations in the sample are from precisely the same depth as those from the reference. Setting the transmit focus well beyond the depth range used to compute attenuation values minimized the bias.
DOI: 10.1006/uimg.1993.1021
发表时间: 1993-10-01
期刊: ULTRASONIC IMAGING
影响因子: 2.3
作者:
ZAGZEBSKI, JA;LU, ZF;YAO, LX
通讯作者: YAO, LX
DOI: 10.1177/016173469802000302
发表时间: 1998-07-01
期刊: ULTRASONIC IMAGING
影响因子: 2.3
作者:
Ribault, M;Chapelon, JY;Gelet, A
通讯作者: Gelet, A
DOI: 10.1109/tuffc.2003.1197963
发表时间: 2003-04-01
影响因子: 3.6
作者:
Wear, KA
通讯作者: Wear, KA
DOI: 10.1109/58.764855
发表时间: 1999-05-01
影响因子: 3.6
作者:
Li, YD;Zagzebski, JA
通讯作者: Zagzebski, JA
DOI: 10.1016/j.ultras.2006.06.061
发表时间: 2006-12-22
期刊: ULTRASONICS
影响因子: 4.2
作者:
Napolitano, David;Chou, Ching-Hua;Steins, Robert
通讯作者: Steins, Robert