PHYSICAL MEASUREMENTS WITH HIGH-ENERGY RADIOACTIVE BEAMS
PHYSICAL MEASUREMENTS WITH HIGH-ENERGY RADIOACTIVE BEAMS
复制标题
DOI:
10.2307/3576001
复制
发表时间:
1982-01-01
影响因子:
3.4
通讯作者:
LLACER, J
中科院分区:
文献类型:
--
作者:
CHATTERJEE, A;SAUNDERS, W;LLACER, J
Physical measurements were made with high-energy radioactive beams (positron emitters) produced as secondary particles from a heavy-particle accelerator. Data are presented for water-equivalent thickness of a silicon diode, a comparison of Bragg peak ionization depth vs. stopping depth, and differential stopping depths when a beam is intercepted by heterogeneous materials in the orthogonal direction. A special positron-emitting bean analyzing (PEBA) system was used to form images of the stopped radioactive beam. These measurements will have direct impact on charged-particle radiotherapy [for cancer], since the precise range of beams of charged particles to targets within patients can be measured and used for treatment planning. During the treatments the stopping point of the beam can be monitored to verify that the treatment is being delivered as planned.