Strain and torsion quantification in mouse hearts under dobutamine stimulation using 2D multiphase MR DENSE.
Strain and torsion quantification in mouse hearts under dobutamine stimulation using 2D multiphase MR DENSE.
复制标题
使用 2D 多相 MR DENSE 对多巴酚丁胺刺激下的小鼠心脏应变和扭转进行定量。
DOI:
10.1002/mrm.22530
复制
发表时间:
2010
影响因子:
3.3
通讯作者:
Yu,Xin
中科院分区:
文献类型:
--
作者:
Zhong,Jia;Yu,Xin
In this study, a 2D multiphase magnetic resonance displacement encoding with stimulated echoes (DENSE) imaging and analysis method was developed for direct quantification of Lagrangian strain in the mouse heart. Using the proposed method, <10 ms temporal resolution and 0.56 mm in‐plane resolution were achieved. A validation study that compared strain calculation by displacement encoding with stimulated echoes and by magnetic resonance tagging showed high correlation between the two methods (R2> 0.80). Regional ventricular wall strain and twist were characterized in mouse hearts at baseline and under dobutamine stimulation. Dobutamine stimulation induced significant increase in radial and circumferential strains and torsion at peak systole. A rapid untwisting was also observed during early diastole. This work demonstrates the capability of characterizing cardiac functional response to dobutamine stimulation in the mouse heart using 2D multiphase magnetic resonance displacement encoding with stimulated echoes. Magn Reson Med, 2010. © 2010 Wiley‐Liss, Inc.