AC transport current loss of horizontally attached Bi-2223/Ag tapes
AC transport current loss of horizontally attached Bi-2223/Ag tapes
复制标题
水平连接的 Bi-2223/Ag 磁带的交流传输电流损耗
DOI:
10.1109/tasc.2004.830920
复制
发表时间:
2004
影响因子:
1.8
通讯作者:
K. Ryu
中科院分区:
文献类型:
--
作者:
Seyong Choi;W. Nah;Jung Ho Kim;J. Joo;Young;K. Ryu
In this paper we investigate AC-transport current loss and current distribution of Bi-2223/Ag tapes which are arranged in edge-to-edge configuration. A numerical code was developed to estimate the transport current loss and the current distribution across the tapes. AC-loss measurements were also performed and the coincidence between the calculated and measured values is excellent. AC losses of the horizontally-attached tapes were larger than just a simple summation of each tape's loss but not as large as the loss from Norris equation. Discussions on these results are addressed using the current distribution obtained from numerical analysis.