Criteria of choice of the front-end transistor for low-noise preamplification of detector signals at sub-microsecond shaping times for X- and gamma-ray spectroscopy
Criteria of choice of the front-end transistor for low-noise preamplification of detector signals at sub-microsecond shaping times for X- and gamma-ray spectroscopy
复制标题
DOI:
10.1016/s0168-9002(96)00474-3
复制
发表时间:
1996-10-01
影响因子:
1.4
通讯作者:
DeGeronimo, G
中科院分区:
文献类型:
--
作者:
Bertuccio, G;Pullia, A;DeGeronimo, G
We present an analysis of the electronic noise contributions which limit the resolution of X- and gamma-ray spectrometers employing semiconductor detectors operating at room temperature and at signal processing times in the sub-microsecond range. The figures of merit of the front-end transistors, relevant to attain the highest resolution, are put in evidence. It is shown how the correlation between the gate and drain current noises in FETs plays a significant role in the equivalent noise charge of a charge preamplifier. Some state of the art devices, belonging to different technologies, JFET, MOSFET, MESFET and HFET, are examined.