SECONDARY BEAM COURSE FOR THE MEDICAL USE AT HIMAC

SECONDARY BEAM COURSE FOR THE MEDICAL USE AT HIMAC
复制标题

HIMAC 医疗用途的二次光束课程

DOI:
--
复制
发表时间:
1998
期刊:
--
影响因子:
--
通讯作者:
N. Matsufuji
N. Matsufuji
中科院分区:
--
文献类型:
--
作者:
A. Kitagawa;S. Kouda;T. Nishio;M. Torikoshi;K. Noda;T. Murakami;M. Suda;T. Tomitani;T. Kanai;Y. Futami;H. Yamashita;N. Matsufuji

文献摘要

被引文献

相似文献

为了验证碳束癌症治疗中的深度剂量分布,正电子发射器束是一种很有前途的工具。为此,我们建造了次梁课程并开始了梁测试。所得C束收率为0.2%,纯度为97%。为了测量该光束的停止点,正电子相机和 PET 的初步光束测试正在进行中。我们还开始构建辐照系统,其中将使用 C 和 C 束点扫描方法。
To verify the depth dose distribution in the cancer treatment with carbon beam, the beam of positron emitter is a promising tool. For this purpose we have constructed a secondary beam course and have started the beam test. The obtained yield rate of the C beam was 0.2% with a purity of 97%. To measure the stopping point of this beam, the preliminary beam tests of positron camera and a PET are now underway. We have also started to construct the irradiation system, where the spot scanning method will be used with C and C beams.