Cyclic experiments on isolated steel sheet connections for CFS framed steel sheet sheathed shear walls with new configurations
Cyclic experiments on isolated steel sheet connections for CFS framed steel sheet sheathed shear walls with new configurations
复制标题
新构型CFS框架钢板剪力墙孤立钢板连接循环试验
DOI:
10.1016/j.engstruct.2021.112805
复制
发表时间:
2021
影响因子:
5.5
通讯作者:
Schafer, Benjamin W.
中科院分区:
文献类型:
--
作者:
Zhang, Zhidong;Singh, Amanpreet;Derveni, Fani;Torabian, Shahabeddin;Peterman, Kara D.;Hutchinson, Tara C.;Schafer, Benjamin W.
The main objective of this research is to experimentally characterize the performance of isolated single sheathing-to-framing fastener connections under cyclic load as utilized in emerging classes of cold-formed steel (CFS) framed steel sheet sheathed shear walls used for seismic lateral resistance. New shear wall variations include the use of steel sheet sheathing sandwiched between framing members (i.e., mid-ply) and the use of heavy hollow structural sections (HSS) chord members with the thin steel sheet sheathing attached by power actuated fasteners (PAF) to the HSS. The cyclic nonlinear response of the framing to steel sheet fastener connection is fundamental for simulating the seismic performance of steel sheet sheathed shear walls. Minimal cyclic fastener-level test data under shear exists for these new configurations. A unique lap shear test following AISI S905 was designed to study and characterize the cyclic fastener connection behavior. The specimens were loaded with an asymmetric cyclic loading protocol which intentionally buckles the thin sheet in the compression direction, and progressively increases in the tension direction. Sixty-three tests covering a wide range of framing thickness, sheet thickness, fastener type and size were completed. Each connection configuration is characterized with a multi-linear backbone curve ready for use in numerical shear wall models. The tested fastener configurations exhibit excellent performance as fastener tilting is largely or completely eliminated in these configurations, and connection degradation from buckling of the steel sheet is minimized. It is also shown that AISI S100 connection strength provisions are applicable to the tested connections.
登录
查看更多内容
DOI:
--
发表时间:
2020
期刊:
影响因子:
--
作者:
Amanpreet Singh;Xiang Wang;S. Torabian;T. Hutchinson;K. Peterman;B. Schafer
通讯作者:
B. Schafer
DOI:
--
发表时间:
2018
期刊:
影响因子:
--
作者:
Y. Shi;S. Torabian;B. Schafer;W. S. Easterling;M. Eatherton
通讯作者:
M. Eatherton
DOI:
--
发表时间:
2019
期刊:
影响因子:
--
作者:
Jia Wu
通讯作者:
Jia Wu
DOI:
--
发表时间:
2021
期刊:
影响因子:
--
作者:
S. Torabian;B. Schafer
通讯作者:
B. Schafer
DOI:
--
发表时间:
1996
期刊:
影响因子:
--
作者:
Randy L. Daudet;R. A. Laboube
通讯作者:
R. A. Laboube