A 14 cm×36 cm volume negative ion source producing multi‐ampere H− ion beams
A 14 cm×36 cm volume negative ion source producing multi‐ampere H− ion beams
复制标题
产生多安培 H− 离子束的 14 cm×36 cm 体积负离子源
DOI:
10.1063/1.1141233
复制
发表时间:
1990
影响因子:
1.6
通讯作者:
M. Seki
中科院分区:
文献类型:
--
作者:
M. Hanada;T. Inoue;H. Kojima;Y. Matsuda;Y. Ohara;Y. Okumura;Kazuhiro Watanabe;M. Seki
A large volume negative ion source, which has a newly devised magnetic filter called a PG filter, was designed and tested. The PG filter produces a uniform magnetic filter field over a large extraction area of 14×36 cm2 by flowing a high current through the plasma grid itself. By optimizing the filter strength, we succeeded to produce 3.4‐A 75‐keV negative hydrogen ion beams for 50 ms from 253 apertures of 11.3 mm diam with an average current H− density of 13 mA/cm2.