提出了μ单元疲劳试验的新概念。通过使细胞反复往复穿过微通道的喉部,测量细胞的动态变形行为。我们定义了一个新的指数的疲劳特性的细胞的往复运动导致规定的恢复率的数量。该测试系统由压电陶瓷驱动器、高速视觉传感器和带喉道的微通道组成。通过使用红细胞(RBC)进行初步实验。结果表明,可以根据细胞的疲劳特性来评估细胞的激活水平。
A new concept of μ-cell fatigue test is proposed. By reciprocating a cell across the throat of a micro channel repeatedly, the dynamic deformation behavior of the cell is measured. We define a new index of fatigue characteristics of cells as the number of reciprocatory motion leading to a prescribed recovery ratio. The test system is composed of a piezoelectric (PZT) actuator, a high speed vision sensor and a micro channel with a throat. Preliminary experiments were conducted by using Red Blood Cells (RBCs). The result suggested that the activation level of a cell can be evaluated based on its fatigue characteristics.
DOI: 10.1182/blood.v99.3.1060
发表时间: 2002-02-01
期刊: BLOOD
影响因子: 20.3
作者:
Glenister, FK;Coppel, RL;Cooke, BM
通讯作者: Cooke, BM